Description
Standards
International : EN 45545-2 (HL3); EN 50382-2Description
Application
These specific extra flexible cables with mechanical reinforced insulation are dedicated to be used as jumper.
Construction
- Conductor
Extra Flexible class 6 copper according to IEC 60228
* tinned copper for 120°C Class
* plain copper for 150°C Class - Separator
Unweaved tape - Insulation
Cross-linked silicone type EI 111, according to EN 50382-1 with an embedded polyester reinforcement.
Colour : black outer layer
Marking
FLAMEX SI - EN 50382-2 - 3600 V - cross-section mm² - FXZ - class temperature (120°C or 150°C) - NEXANS 279 - week/year
Guide to use
Cabling rules are given according to EN 50343
- Minimum bending radius (static) : 4 x outer cable diameter
- Minimum bending radius (dynamic) : 6 x outer cable diameter
- Pulling tensible force (dynamic) during installation : 50 N/mm² of copper size
- Mechanical (static) tensible force : 15N/mm² of copper size
- Permissible current carrying capacities : value and calculation method are given in EN 50355
Standards
Construction according to EN 50382-2
Characteristics
Construction characteristics | |
---|---|
Insulation | High temperature silicone |
Halogen free | EN 50267 |
Usage characteristics | |
Chemical resistance | Good |
Flame retardant | EN 60332-1-2 |
Fire retardant | IEC 60332-3-24 |
Smoke density | EN/IEC 61034-2 |
Gases corrosivity | IEC 60754 |
Gases toxicity | EN 50305-9.2 |
Operating temperature, range | -50 .. 120°C |
Specific characteristics | |
See all products | |
|