Description
Standards
International : EN 45545 - HL3; EN 50264-3-1; IEC 60228Description
Applications
For protected installation in railway vehicles (locomotives, trains, trolley-busses etc.), switching station and control panels. Installation in cable ducts, pipes and tubes.
Current carrying capacity according to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type EI 109 acc. to EN 50264-3-1
Oil, diesel, ozone and UV resistant
Colour: black or optionally green/yellow or other colours
Cable marking
Printing white:
FLAMEX EN 50264-3-1 600V mm² M (N)HXAF 0,6/1kV I NEXANS I WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Sheath colour | Black |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Smoke density | IEC 61034-2 & NFF 16101 |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | IEC 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Bending factor when laying | 5(xD) |
Bending factor when installed | 3(xD) |
Oil resistance | Yes |
Ozone resistance | Yes |
U.V resistance | Yes |
Specific characteristics | |
See all products | |
|
Products and services
Docs and info
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 0.6/1 (1.2) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 0.9 kV DC |
Testing AC voltage (5 minutes) |
U = 3.5 kV |
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |
Selling information
Special conditions relating to temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.