Description
Standards
International : EN 45545 - HL3; EN 50264-3-2; IEC 60228Description
Applications
For protected installation in railway vehicles (locomotives, trains, trolley-busses etc.), switching station and control panels. Installation in cable ducts, pipes and outside.
Current capacity acc. to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type El 109 acc. to EN 50264-1
Colour: black or green/yellow (if cable type is nxG)
Assembly
Option: A halogen free foil could be served.
3. Screen
Copper wire braid acc. to EN 50264-3-2, halogen-free separator
4. Outer sheath
Cross-linked compound type EM 104 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Cable marking
Printing white
FLAMEX EN 50264-3-2 600V n X (G) ... (mm²) MM S (N)HXCSLOE I NEXANS I
WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Colour | Black |
Conductor material | Tinned copper |
Conductor flexibility | Flexible stranded |
Sheath colour | Black |
With Green/Yellow core | No |
Dimensional characteristics | |
Number of cores | 3 |
Conductor cross-section | 1.5mm² |
Minimum outer diameter | 8.3mm |
Maximum outer diameter | 9.3mm |
Approximate weight | 120kg/km |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 0.6/1 kV |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Smoke density | IEC 61034-2 & NFF 16101 |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | EN 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Bending factor when laying | 8(xD) |
Bending factor when installed | 4(xD) |
Oil resistance | Yes |
Ozone resistance | Yes |
U.V resistance | Yes |
Ambient static operating temperature, range | -40 .. 120°C |
Max. conductor temperature in service | 90°C |
Short-circuit max. conductor temperature | 200°C |
Docs and info
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 0.6/1 (1.2) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 0.9 kV DC |
Testing AC voltage (5 minutes) |
U = 3.5 kV |
Coupling resistance ≤ 30 MHz |
≤ 120 Ohm/km |
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |
Selling information
Special conditions relating to temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.