Description
Standards
International : EN 45545 - HL3; EN 50264-3-1; IEC 60228Description
Applications
For use in railway vehicles (trains, locomotives, trolley-busses, etc.), switching stations and control panels.
Installation in cable ducts, tubes and outside. For wiring in switching stations and distribution boards up to 1000 V, this cable is short-circuit and earth fault save.
Current-carrying capacity acc. to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2-HL3.
Design
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type El 109 acc. to EN 50264-1
3. Screen
Halogen-free foil, tinned copper wire braid, halogen-free separator
4. Outer sheath
Cross-linked compound type EM 104 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Cable marking
Ink marking white e.g.:
Flamex EN 50264-3-1 1800V (mm²) MM S (N)SHXAFCOE 1.8/3 kV I NEXANS I WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Sheath colour | Black |
Insulation | EPR |
Screen | Tinned copper braid |
Conductor material | Tinned copper |
Conductor flexibility | Flexible stranded |
Dimensional characteristics | |
Conductor cross-section | 120mm² |
Minimum outer diameter | 21.9mm |
Maximum outer diameter | 22.9mm |
Approximate weight | 1430kg/km |
Number of cores | 1 |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 1.8 / 3 kV |
Usage characteristics | |
Fire load | 1.8kWh/m |
Operating temperature, range | -40 .. 90°C |
Smoke density | IEC 61034-2 & NFF 16101 |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | EN 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Bending factor when laying | 10(xD) |
Oil resistance | Yes |
Ozone resistance | Yes |
U.V resistance | Yes |
Short-circuit max. conductor temperature | 200°C |
Docs and info
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 1.8/3 (3.6) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 2.7 kV DC |
Testing AC voltage (5 minutes) |
U = 6.5 kV |
Coupling resistance 10 kHz – 30 MHz, > 16 mm² |
≤ 50 Ohm/km |
Coupling resistance 10 kHz – 30 MHz, 2.5 mm² - 16 mm² |
≤ 150 Ohm/km |
Selling information
Special conditions relating to temperature and bending radii (e.g. by compelled guidance into cluthes, wagon transition and boogies) on request.