Description
Standards
International : EN 45545 - HL3; EN 50264-3-2; IEC 60228Description
Applications
For protected installation in railway vehicles (locomotives, trains, trolley-busses etc.), switching station and control panels. Installation in cable ducts, pipes and outside.
Current capacity acc. to EN 50343 as well as VDE 0298 part 4.
Complies with performance requirements acc. to EN 45545-2 - HL3.
Design
1. Conductor
Flexible stranded tinned copper, class 5 acc. to IEC 60228
Optional halogen-free separator tape
2. Insulation
Cross-linked compound type El 109 acc. to EN 50264-1
3. Outer sheath
Cross-linked compound type EM 104 acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black
Cable marking
Printing white:
FLAMEX EN 50264-3-2 600V n X (G) ... (mm²) MM (N)HXSLOE I NEXANS I
WW-YYYY
Characteristics
Construction characteristics | |
---|---|
Halogen free | EN 50267-2-1 & EN 60684-2 |
Sheath colour | Black |
Conductor material | Tinned copper |
Conductor flexibility | Flexible stranded |
With Green/Yellow core | No |
Dimensional characteristics | |
Number of cores | 4 |
Conductor cross-section | 6mm² |
Minimum outer diameter | 12.2mm |
Maximum outer diameter | 14.0mm |
Approximate weight | 353kg/km |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 0.6/1 kV |
Usage characteristics | |
Operating temperature, range | -40 .. 90°C |
Gases corrosivity | EN 50267-2-2 |
Gases toxicity | EN 50305-9.2 |
Flame retardant | IEC 60332-1-2 |
Fire retardant | EN 60332-3-24 & EN 60332-3-25 |
Bending factor when laying | 5(xD) |
Bending factor when installed | 4(xD) |
Oil resistance | Yes |
Ozone resistance | Yes |
Ambient static operating temperature, range | -40 .. 120°C |
Max. conductor temperature in service | 90°C |
Short-circuit max. conductor temperature | 200°C |
U.V resistance | Yes |
Docs and info
Electrical Properties
Nominal voltage |
Uo/U (Umax) = 0.6/1 (1.2) kV |
Max. operating voltage in DC installations, one-sided earthed |
Vo= 0.9 kV DC |
Testing AC voltage (5 minutes) |
U = 3.5 kV |
Max. operating temperature at conductor
Conductor at normal operation |
≤ 90 °C/250.000 h |
|
≤ 120 °C/20.000 h |
Conductor under short-circuit conditions (tinned) |
≤ 200 °C |
Selling information